Dongguan Zhongli Instrument Technology Co., Ltd.

Providing one-stop service for global laboratories, customer's satisfaction is our ultimate goal!

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Helmet Testing Machine /

Motorcycle Helmet Collision Penetration Resistance Performance Testing Machine

Contact Now
Dongguan Zhongli Instrument Technology Co., Ltd.
Visit Website
City:dongguan
Province/State:guangdong
Contact Person:MsFiona Zhong
Contact Now

Motorcycle Helmet Collision Penetration Resistance Performance Testing Machine

Ask Latest Price
Video Channel
Brand Name :ZL
Model Number :ZL-1814
Certification :ISO
Place of Origin :China
MOQ :1 set
Price :Negotiable
Payment Terms :T/T, L/C, Western Union
Supply Ability :100 set per month
Delivery Time :10-15 days
Packaging Details :Motorcycle Helmet Collision Penetration Resistance Performance Testing Machine is Packaged within wooden case
Product name :Motorcycle Helmet Collision Penetration Resistance Performance Testing Machine
Power :220v 50hz
Maximum impact height :3M
Acceleration sensor measuring range :0-1000g
Measurement accuracy :0.1ms
Collection frequency response range :0-1000Hz
Warranty :12 month
Key words :Collision Penetration Resistance
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Motorcycle Helmet Collision Penetration Resistance Performance Testing Machine

Equipment Description:


Mainly used in motorcycle helmets and the special test equipment. It is the various helmet manufacturers, testing agencies, universities, research institutes and other special test equipment. The machine uses high-precision acceleration sensors to ensure accurate and reliable measurement, simple, quickly and accurately.

Corresponding standard: GB811-1998 standard


Technical parameter:

the maximum impact height

3000MM (impact and penetration to

meet the two measurement height)

the acceleration sensor measuring range 0-1000g
the height of the helmet A (1829 ± 2mm, 1384 ± 2mm)
B (1600 ± 2mm)
falling helmet Weight

4 kg (trumpet), 5 kg (medium),

6 kg (large) each one

the band cut-off point -2.5 ~-4DB
the attenuation slope -9 ~ -24DB/oct
reaction time measurement accuracy 0.1ms
the measurement uncertainty 5%
the collection frequency response range 0-1000Hz
power supply VC380V, 50Hz